| Location | Charlotte, NC |
|---|---|
| Date | 2026-11 |
| Appliance | InstaView French door refrigerator with ice and water dispenser |
| Model | LG LFXS26596S |
| Production date | November 2020 |
| Part replaced | Evaporator fan motor |
| Refrigerant | R600a, 2.12 oz |
| Problem | Fresh-food section not cooling — 46.8°F measured before repair |
| Repair | Replaced the evaporator fan motor; fresh-food section back to 38.5°F |
Photos from this job




About this repair
The LG evaporator fan inside the freezer moves cold air to both compartments. When it stops — often because it is frozen in ice from a defrost failure — the fridge warms while the freezer stays partly cold, and FF or rF may appear. Check the coil for frost before replacing the fan. We repair evaporator fans and defrost systems same day in Charlotte and nearby cities.
Read the full guide: LG Evaporator Fan Motor Replacement →